Smith Chart Matcher

Enter an antenna or load impedance, or click a point on the chart. You get VSWR, return loss and mismatch loss, every L-network that matches it with real E-series parts, and the bandwidth each one actually delivers.

Runs entirely in your browser. Nothing is uploaded.

1 · Load

Ω
Ω
Ω
Hz

2 · Match

dB

Load

VSWR
—
Return loss
—
Mismatch loss
—
Γ (S11)
—
Power reflected
—
Impedance Z
—
Normalized z
—
Equivalent
—
—

Smith chart

Click anywhere on the chart to set the load. The solid line is the selected match, taken from the load to the centre.

Hover for z, Γ and VSWR

L-networks

Every circuit that matches this load to Z0, listed from the load toward the source. Lowpass circuits also attenuate harmonics.

#TypeAt the loadToward sourceLoaded Q

Single shunt stub

Distance from the load to the stub, and the stub length. Lengths use the velocity factor above. Short-circuited stubs are easiest to build.

#Stub atShorted stubOpen stub

Quarter-wave transformer

Slide along the line to a point where the impedance is real, then add a λ/4 section.

#Insert atZ thereSection ZtSection lengthBandwidth
// How it works

Reading the chart, and where the matches come from

The Smith chart is the reflection coefficient plane with the impedance grid drawn on it. A load Z, referred to the system impedance Z0, lands at:

Γ = (Z − Z0) / (Z + Z0) VSWR = (1 + |Γ|) / (1 − |Γ|) return loss = −20·log10|Γ| mismatch loss = −10·log10(1 − |Γ|²)

The centre is a perfect match. Circles are constant resistance, arcs are constant reactance, and the dashed circle through your load is its VSWR circle. Moving toward the generator along a line rotates clockwise around that circle by 2βd.

L-networks

Two reactive elements are enough to match any load with a positive resistance, as long as the circuit type fits the load. In admittance form, Y = G + jB:

shunt element at the load, series toward the source needs G ≤ 1/Z0 B' = ±√(G/Z0 − G²) B_shunt = B' − B X_series = −Im(1 / (G + jB')) series element at the load, shunt toward the source needs R ≤ Z0 X' = ±√(R·(Z0 − R)) X_series = X' − X B_shunt = X' / (R·Z0)

That is up to four circuits. A positive series reactance is an inductor, X = ωL. A negative one is a capacitor, X = −1/(ωC). Shunt susceptance is the mirror: B = ωC or B = −1/(ωL). The loaded Q equals |B'|/G or |X'|/R, and it sets how narrow the match is.

Standard values and bandwidth

Real parts come from E-series values, so the match at f0 is never perfect. The tool rounds each part to the nearest standard value and then sweeps the whole network over frequency. A reactive load is treated as a series inductor (X > 0) or capacitor (X < 0) that scales with frequency, and parts are ideal. The bandwidth is the contiguous range around f0 where return loss stays at or above your spec.

Stub and quarter-wave

stub: t = tan(βd) = [x ± √(r·((1 − r)² + x²))] / (r − 1) z = r + jx = Z/Z0 shorted stub cot(βl) = b open stub tan(βl) = −b (y = 1 + jb at the stub) λ/4: Zt = √(Z0 · Zreal) Zreal = Z0·VSWR at a voltage maximum, Z0/VSWR at a minimum Δf/f0 = 2 − (4/π)·acos( Γm/√(1 − Γm²) · 2√(Z0·Zreal) / |Zreal − Z0| )

Limits

References

  1. D. M. Pozar, Microwave Engineering, 4th ed., Ch. 2.3 (reflection coefficient, VSWR, return loss), §5.1 (lumped-element L-section matching, Example 5.1), §5.2 (single-stub tuning), §5.4 (single-section quarter-wave transformer).
  2. C. Bowick, RF Circuit Design, Ch. 4: L-network matching, Q = √(Rhigh/Rlow − 1).
  3. P. H. Smith, "Transmission Line Calculator", Electronics, Jan 1939.
  4. IEC 60063, preferred number series for resistors and capacitors (E6, E12, E24, E96).