EMC Pre-Compliance Checker
Answer questions about your clocks, cables, enclosure, grounding and power input. You get a risk score, a ranked list of what is likely to fail, and your clock harmonics and cable resonances placed against the emission limits.
1 · Clocks and signals
2 · PCB design
3 · Enclosure and cables
4 · Power supply
5 · Regulatory target
Risk score
Findings
Ranked critical first. Each one names the frequency range it affects and the standard it puts at risk.
Key numbers from your inputs
Emission limits and your frequencies
Radiated limit for the selected standard, both classes, scaled to a 10 m distance. Vertical lines are clock harmonics; dots are cable quarter-wave resonances.
Clock harmonics in the radiated band
| n | Frequency | Level vs fundamental | Limit | At |
|---|
Cable and switcher numbers
| Cable resonance | Frequency | Limit |
|---|
Switching-supply harmonics in the conducted band
| n | Frequency | Mains QP limit |
|---|
What the score means, and where the numbers come from
The checker runs 38 fixed rules against your answers. Each rule is a yes/no test that experience says correlates with a failed emissions or immunity scan, and each has a severity. The same answers always give the same findings and the same score.
The score is a ranking aid for design reviews. It is not a prediction of a lab result: a design with a perfect score can still fail on one bad cable, and a design with a poor score can pass on a good day.
Formulas behind the numbers
A 50 % square wave has a fundamental of 2/π of its peak-to-peak value and no even harmonics. A finite rise time adds a second corner at 1/(π·t_r) above which the envelope falls 40 dB per decade instead of 20.
Limits used
- CISPR 32 / EN 55032 radiated, 10 m, quasi-peak: Class B 30 dBµV/m (30–230 MHz) and 37 dBµV/m (230–1000 MHz). Class A 40 and 47 dBµV/m.
- FCC 47 CFR 15.109 radiated: Class B at 3 m, 100 / 150 / 200 / 500 µV/m in the bands 30–88 / 88–216 / 216–960 / above 960 MHz. Class A at 10 m, 90 / 150 / 210 / 300 µV/m.
- Mains conducted, quasi-peak (CISPR 32 and FCC 15.107): Class B 66 falling to 56 dBµV over 0.15–0.5 MHz, 56 to 5 MHz, 60 to 30 MHz. Class A 79 and 73 dBµV.
- Limits are scaled between distances at 20 dB per decade, which holds in the far field only. The IEC 61000-4-x option is an immunity standard with no emission limits, so the numbers fall back to CISPR 32.
Limits of this tool
- It sees your answers, not your layout. It cannot know that a clock trace crosses a split in the ground plane.
- Harmonic levels are relative. Absolute radiated field depends on trace loop area, cable current and enclosure, which a questionnaire does not capture.
- Cable resonances assume free space and a cable against a ground. Real cables resonate lower with insulation and higher with a loaded end. Treat them as places to look with a near-field probe.
- Limits above 1 GHz, intentional radiators (FCC Part 15C, RED), and automotive CISPR 25 are named in the findings but not tabulated. Always check the current edition of each standard.
References
- CISPR 32 (Ed. 2.1, 2019), Electromagnetic compatibility of multimedia equipment: emission requirements. EN 55032 is the harmonized European text.
- 47 CFR Part 15 Subpart B, Sections 15.107 (conducted) and 15.109 (radiated).
- C. R. Paul, Introduction to Electromagnetic Compatibility, 2nd ed., Wiley 2006: trapezoidal-pulse spectrum (Ch. 3) and shielding (Ch. 8).
- H. W. Ott, Electromagnetic Compatibility Engineering, Wiley 2009: apertures and slots (Ch. 6), cable emissions.
- H. Johnson and M. Graham, High-Speed Digital Design, Prentice Hall 1993: BW = 0.35 / t_rise.
- IEC 61000-4-2 (ESD), IEC 60601-1-2 (medical), CISPR 25 and ISO 11452 (automotive).
Heading into the test lab?
Kyros designs for EMC from the first schematic: stackup, filtering, cable strategy and pre-scans, so the lab visit confirms the design instead of discovering it.
