Kyros Engineering Engineering Tools
Home › Tools › EMC Pre-Compliance Checker
// Compliance tools Proto v0.1CISPR 32FCC 15B38 design rules

EMC Pre-Compliance Checker

Answer questions about your clocks, cables, enclosure, grounding and power input. You get a risk score, a ranked list of what is likely to fail, and your clock harmonics and cable resonances placed against the emission limits.

Runs entirely in your browser. Nothing is uploaded.

1 · Clocks and signals

MHz
ns
kHz
High-speed interfaces present

2 · PCB design

mm

3 · Enclosure and cables

mm
m
Cable types present

4 · Power supply

5 · Regulatory target

Risk score

0 / 100
—

Findings

Ranked critical first. Each one names the frequency range it affects and the standard it puts at risk.

Key numbers from your inputs

Emission limits and your frequencies

Radiated limit for the selected standard, both classes, scaled to a 10 m distance. Vertical lines are clock harmonics; dots are cable quarter-wave resonances.

Clock harmonics in the radiated band

nFrequencyLevel vs fundamentalLimitAt

Cable and switcher numbers

Cable resonanceFrequencyLimit

Switching-supply harmonics in the conducted band

nFrequencyMains QP limit
// How it works

What the score means, and where the numbers come from

The checker runs 38 fixed rules against your answers. Each rule is a yes/no test that experience says correlates with a failed emissions or immunity scan, and each has a severity. The same answers always give the same findings and the same score.

score = min(100, 18·critical + 10·high + 5·medium + 2·low) (no findings scores 5) 0–30 low risk: likely to pass 31–60 medium risk: issues expected 61–100 high risk: likely to fail

The score is a ranking aid for design reviews. It is not a prediction of a lab result: a design with a perfect score can still fail on one bad cable, and a design with a poor score can pass on a good day.

Formulas behind the numbers

edge bandwidth BW = 0.35 / t_rise clock harmonics f_n = n · f_clk, counted from 30 MHz to 1 GHz trapezoid spectrum |c_n| = 2d · |sinc(nπd)| · |sinc(nπ·t_r/T)| d = duty (0.5 assumed) cable λ/20 corner = c / (20·L); quarter-wave f = (2k−1)·c / (4·L) slot f_res = c / (2·l); SE = 20·log10(λ / 2l) dB, 0 dB once l ≥ λ/2 board cavity f = c / (2·L·√εr), εr = 4.5 (FR4)

A 50 % square wave has a fundamental of 2/π of its peak-to-peak value and no even harmonics. A finite rise time adds a second corner at 1/(π·t_r) above which the envelope falls 40 dB per decade instead of 20.

Limits used

Limits of this tool

References

  1. CISPR 32 (Ed. 2.1, 2019), Electromagnetic compatibility of multimedia equipment: emission requirements. EN 55032 is the harmonized European text.
  2. 47 CFR Part 15 Subpart B, Sections 15.107 (conducted) and 15.109 (radiated).
  3. C. R. Paul, Introduction to Electromagnetic Compatibility, 2nd ed., Wiley 2006: trapezoidal-pulse spectrum (Ch. 3) and shielding (Ch. 8).
  4. H. W. Ott, Electromagnetic Compatibility Engineering, Wiley 2009: apertures and slots (Ch. 6), cable emissions.
  5. H. Johnson and M. Graham, High-Speed Digital Design, Prentice Hall 1993: BW = 0.35 / t_rise.
  6. IEC 61000-4-2 (ESD), IEC 60601-1-2 (medical), CISPR 25 and ISO 11452 (automotive).

Heading into the test lab?

Kyros designs for EMC from the first schematic: stackup, filtering, cable strategy and pre-scans, so the lab visit confirms the design instead of discovering it.

Talk about your project →